NORDTEK DANMARK - EI66 - Encapsulated Vertical Mount 50/60Hz Transformer - 28-63VA - nordtek.biz

Tell a friend Enquiry print

EI66 - Encapsulated Vertical Mount 50/60Hz Transformer - 28-63VA

Our comprehensive selection of products also includes a series of EI66 safety transformers for pbc- or vertical mounting.

High-quality encapsulated vacuum potted transformers. Output power from 28VA.

  Pin and Transformer height   Print Layout - EI66 Transformer   EI66 - Encapsulated PCB Mount Transformer 50/60Hz - 28-63VA   EI66 - Encapsulated Vertical Mount Transformer 50/60Hz- 28-63VA  
 
View from PCB   Solder pins 0.8 mm Ø  - Grid 5 mm


Type Max. Ambient temperature Pin connections Pin connections * Stack
Height
mm
Case
Height
(H) mm
Weight
g
 EI66-12A/7.../... 70°C/B 6...40V - 28.00 VA 2x6...20V - 2x14.00 VA nkf 23.0 48.5 780
 EI66-12F/7.../... 70°C/B 6...40V - 31.00 VA 2x6...20V - 2x15.50 VA bkf 23,0 48.5 780
 EI66-12A/4.../... 40°C/B 6...40V - 33.50 VA 2x6...20V - 2x16.75 VA nkf 23.0 48.5 780
 EI66-12F/4.../... 40°C/B 6...40V - 40.00 VA 2x6...20V - 2x20.00 VA bkf 23.0 48.5 780
 EI66-32A/7.../... 70°C/B 6...40V - 37.00 VA 2x6...20V - 2x18.50 VA nkf 30.0 55.8 950
 EI66-32F/7.../... 70°C/B 6...40V - 41.00 VA 2x6...20V - 2x20.50 VA bkf 30.0 55.8 950
 EI66-32A/4.../... 40°C/B 6...40V - 45.00 VA 2x6...20V - 2x22.50 VA nkf 30.0 55.8 950
 EI66-32F/4.../... 40°C/B 6...40V - 53.50 VA 2x6...20V - 2x26.75 VA bkf 30.0 55.8 950
 EI66-34A/7.../... 70°C/B 6...40V - 42.00 VA 2x6...20V - 2x21.00 VA nkf 34.7 60.2 1,080
 EI66-34F/7.../... 70°C/B 6...40V - 48.00 VA 2x6...20V - 2x24.00 VA bkf 34.7 60.2 1,080
 EI66-34A/4.../... 40°C/B 6...40V - 52.00 VA 2x6...20V - 2x26.00 VA nkf 34.7 60.2 1,080
 EI66-34F/4.../... 40°C/B 6...40V - 63.00 VA 2x6...20V - 2x31.50 VA bkf 34.7 60.2 1,080

  • Approved to EN 60742
  • Vacuum cast
  • Two chamber coil
  • Safety class II
  • Protective system IP 00
  • Conditionally short-circuit proof (*bkf) through built-in temperature fuse,
    or not shorts-circuits proof (*nkf) but protected by external fuse on primary or secondary

Note: If using the conditionally short-circuit proof transformer type (*bkf), no strip conductors may be guided between the primary connecting pins on the component insertion side, because in this area there is an unprotected live soldering terminal.


Variants available on request


Top of page